How can we judge if the air conditioner lacks fluorine?

1, judging from the strength of the hot air blown out

When the air conditioner compressor is running, observe whether the outdoor unit has a thermal sensation, there is a thermal sensation, the freon is enough, no need to make up, no thermal sensation needs further investigation.

But this thermal sensation: if it is very hot, there is a lot of freon, if the thermal sensation is not strong, there may not be enough freon.

2, the air conditioning outdoor unit frequently start and stop, obviously the indoor temperature has not reached the set temperature, the external unit will still stop, it may be caused by fluorine deficiency compressor overheating protection.

3, the outdoor unit noise becomes louder, the noise is large, it may be the installation problem, the outdoor unit inside the pipeline and the shell contact caused by the impact.

The indoor seal is not good, resulting in the leakage of cold air, indoor sunlight, such as a large area of glass Windows, etc., resulting in the actual indoor temperature always can not reach the set temperature, so that the compressor can not stop, it will increase power consumption and noise.

In addition, the lack of fluorine will also make the compressor always in operation, so the noise will be significantly enhanced.

4, the thin copper pipe of the air conditioner is cool, the thick copper pipe is normal temperature, and the indoor air is not cold.

The reason is that the cooling effect is worse, and the thin tube is cooler than the thick tube.

This is caused by the lack of refrigerant, and the cold thin tube indicates that the compressor is working. The thick pipe is normal temperature, but the refrigerant is not enough.

5, the outdoor connection pipeline has obvious oil stains, freon leakage will exist oil stains. Emergency solution Try to find two wrenches, tighten the spot of oil leakage.


Declaration: The content and template of this article are organized from the network, and the copyright belongs to the original author; If there is infringement, please inform in time and contact to delete.


Industrial air conditioning, chemical fiber industrial air conditioningchemical fiber industry refrigeration ,textile industrial air conditioning dust-free workshop coolingventilation pipeline, cooling tower, freezer and other air conditioning units and accessories.

Jiangsu Jincheng Air Conditioning Engineering Co., Ltd. is a comprehensive manufacturer of special air-conditioning equipment design, production, installation, and commissioning of clean room, electricity, tobacco, civil air defense engineering, medical clean room, clean room, electricity, tobacco, civil air defense engineering, medical clean room. Mainly produce JCZK combined air conditioning unit, cooling tower, glass steel ventilated galvanized sheet pipe, stainless steel pipe, polyurethane ventilation pipe and air conditioning accessories, Jincheng air conditioner is wide, the type, the unique model, superior performance, and user Favused.



Keyword:
ADD:No. 18, Rongguang Road, National High-tech Park, Yancheng City, Jiangsu Province Phone: 0086-13705113637 Tell: 0086-0515-88809180 Fax: 0086-0515-88809181 E-Mail: jsjckt@126.com
Copyright ? 2018 All rights reserved
Copyright Jiangsu Jin Cheng Air Conditioning Engineering Co.,Ltd 技術(shù)支持:中國(guó)丙綸網(wǎng)